Download DUCTING Brochure
DUCTING
DUSTECH fabricated accordance with 2005 ‘SMACNA’ standards, ASHRAE standards o as per consultants specifications.
Rectangular duct work has been the main type of duct work in history of HVAC. It is still used today on a greater percentage of commercial projects over any other type. Commercial construction jobs. Every piece we manufacture meets or exceeds standards and project requirements, including Leeds and GREEN CONSTRUCTION STANDARDS.
Dustech is in fabrication of SPIRAL, OVAL & RECTANGULAR DUCTS & ducts products in galvanized iron steel, aluminum, stainless steel, fire rated ducting, linear acoustic insulation and aluminum cladding with an option of painting & powder coating.
RECTANGULAR DUCT
DUSTECH’ Rectangular duct and fitting are factory fabricated to furnish with a high quality line of products in a board range of standard size. To minimize field- ssembly/fabrication cost. Rectangular duct is supplied in lengths upto 4 feet.
Longitudinal seams are typically made with Pittsburgh lock in transverse joint S&C cleat joint, four-bolt connectors are available.
DUSTECH-Rectangular duct work can be shipped completely assembled or knock down in ‘L’ shape. ‘DUSTECH’ standard rectangular products are fabricated to meet SMACNA, ASHREA duct connection/fabrication standards. We can also custom fabricate rectangular duct work for commercial and industrial application according to consultant specification.
This table gives minimum duct wall thickness (gage) for use of flat type joint system. Plan S and hemmed as connectors are limited to 2 in. wg maximum. Slip and drives must not be less than two gages lighter than the duct wall nor below 24 gage. Double S slips must be 24 gage for duct 30in. (762mm) wide or less and 22 gage for greater width.
DUCT DIMENSION (mm) | PRESSURE CLASS (in. wg) | ||||||
Positive or Negative | |||||||
⅟2 | 1 | 2 | 3 | 4 | 6 | 10 | |
200 | 26 | 26 | 26 | 24 | 24 | 24 | 22 |
201-250 | 26 | 26 | 26 | 24 | 22 | 20 | 18 |
251-300 | 26 | 26 | 24 | 22 | 20 | 18 | 16 |
301-350 | 26 | 24 | 22 | 20 | 18 | 18 | |
351-400 | 26 | 22 | 20 | 18 | 18 | 16 | |
401-450 | 26 | 22 | 20 | 18 | 16 | ||
451-500 | 24 | 20 | 18 | 16 | |||
501-550 | 22 | 18 | 16 | 16 | |||
551-600 | 22 | 18 | 16 | 16 | |||
601-650 | 20 | 18 | |||||
651-700 | 18 | 16 | |||||
701-750 | 18 | 16 | |||||
751-900 | 16 |
REINFORCEMENT IS REQUIRED
Duct gage | 26 to 22 | 20 | 18 | 16 |
Minimum flat slip and drive gage | 24 | 22 | 20 | 18 |
DUCT ASSEMBLY ARRANGEMENT
To install the TDF corner, hook first leg of corner under flange. Snap the second leg of TDF corner into place on the duct flange using hammer.
The corner may also be installed by setting the duct upon its end so the flanges are flat against a floor, and then tapping the corner into place with a hammer. The floor supports the flange prevent damage by the procedure.
The preparation is required on only one end of each duct to be joined. Fix the continuous length of gasket on the center of the TDF flange on all four side.
Apply sealent over the corner if small gap occure at the center of the Duct and TDF flange. Place on prepared flange together and insure the alignment by inserting the carrage bolt and then Duct need to be clamped by the standard Dustech cleats at every interval of 6” as shown in the figure with the help of Dustech brouch tool.
Ensure not to use hammer for installation of cleat which may caused damage to the Duct.
SPIRAL DUCT
“DUSTECH” has been established to supply spiral duct and associated fittings our commitment to excellence also extended our leading after sales services and supply program’s “FOR ORDERING TO ON GOING SUPPORT.” Dustech specializes in HVAC & Dust extraction systems. We at Dustech (Roll-o-fab) master the science of air management with the experience of derstanding of practical applications, ensure the project is error free, on time and on budget. We look forward to work with your organization. Thanks for considering “DUSTECH DUCT” For your next project.
“DUSTECH” CAN BE USED IN VAROIUS FIELD SUCH
- As high and low velocity air handling
- General ventilation
- Warm air heating
- Sound absorbers
- Weather proof jacketing of pipeline
- Column formers
- Pier liners
- Dust extraction
- Fume extraction
- Air conditioning
- Tunnel/Mine Ventilation
- Void/Spon Tubling
- Daring/Irrigation
- Pool Fundamation
- Display Props
- Conveyor
- Culvet
- Well Casing
ADVANTAGES OF DUSTECH DUCT
- Energy efficient
- Easy & fast installation
- More straightly per square meter
- Low noise level
- Maintenance friendly
- Modification & extraction is easy
- Low friction losses
- Need less handling arrangement
- Light in weight
- Low project cost
- No accommodation of dust and foreign material in corner being smooth surface
- Can be exposed for good a static
- Used less raw material
AVALIBLITY OF SIZE/MARKED(28 SWG-18AWG)
- Galvano (pb free)
- Stainless steel
- Milled steel
- Galvanized steel
- Aluminum
DUCT FITTINGS
All accessories bends, elbow, reducer off set, endxaps & Tee pieces etc are manufactured high speed modify with accurate dimension
SPIRAL DUCT
DUSTECH DUCT INSTALLATION INSTRUCTION
- Spiral pipe must be cut at straight right angle and be burred.
- Make sure the spiral pipe or large end fitting is ushed all the way in and up to the groove of the small end fitting.
- Secure the slip connection together by using 1/8 sheet metal screws or rivets.
- Place the screw or revits 1”-1⅟2 from the edge of the duct or the large end fitting to avoid cutting the gasket.
SELF SEALING COUPLING
- Between 15% to 25% off you field installation cost lower down.
- Ensure tight seats, assuring clean air quality and energy saving.
- Fitting can be used with most spiral pipe, without calibration.
- Ideal for exposed spiral projects finished duct work is clean with no silver tape
- Fitting is available in a vasity of metal and gauge.
- Fitting can be taken support easily after connection have been made.
- Fitting can be reased,new screw hold can be added without destroying the integrity of self sealing system.
- If at the same point the gasket is damaged the fitting can be used as a part of the self system by shipping on a new o ring.
SELF SEALING COUPLING
SIZE AND WALL THICKNESS CHART
NomMm Inches | NomMm Inches | NomMm Inches |
102 4 | 432 17 | 914 36 |
127 5 | 457 18 | 965 38 |
152 6 | 483 19 | 1018 40 |
178 7 | 508 20 | 1057 42 |
203 8 | 533 21 | 1118 44 |
229 9 | 559 22 | 1168 46 |
254 10 | 584 23 | 1219 48 |
279 11 | 610 24 | 1270 50 |
305 12 | 660 26 | 1321 52 |
330 13 | 711 28 | 1372 54 |
356 14 | 762 30 | 1400 55 |
381 15 | 813 32 | 1500 59 |
406 16 | 864 34 | 1600 63 |
WALL THICKNESS FOR DIAMETERS (OTHER DIAMETERS AND THICKNESS UPON REQUEST)
0.6mm | 0.8mm | 1.0mm | 1.2mm |
OVAL DUCTING AND PIPING
Dustech spiral flat-oval duct is machine formed from Dustech round spiral duct. The flat shape is specifically designed for low head room and restricted space locations which cannot accept round duct.
FLAT-OVAL DUCT DESIGN:
The design of a duct system utilizing flat-oval duct follows the same procedures used with rectangular duct.
- The system is first designed on the basis of circular duct.
- Where space limitations require the use of oval duct, the table has been arranged in a maner that makes its uses similar to tables for rectangular duct and should be used in exactly the same way.
- Spiral flat-oval duct is made only in the sizes listed in tables 1. For maximum economy, select your flat-oval duct size from table 1.
Oval | |||||||||||||||||||||||
Made | |||||||||||||||||||||||
From | |||||||||||||||||||||||
Dia (mm) | 356 | 381 | 406 | 457 | 508 | 559 | 610 | 660 | 711 | 762 | 813 | 864 | 914 | 965 | 1016 | 1047 | 1118 | 1168 | 1219 | 1270 | 1321 | 1372 | |
Nominal Duct Height (A) | 152 | #483 ~279 | #521 ~292 | #560 ~305 | #635 ~318 | #711 ~330 | #800 ~343 | #876 ~368 | #952 ~381 | #1041 ~394 | #1176 ~406 | ||||||||||||
203 | #533 ~343 | #610 ~368 | #686 ~381 | #755 ~406 | #838 ~419 | #927 ~445 | #1003 ~457 | #1092 ~470 | #1168 ~483 | ||||||||||||||
254 | #584 ~394 | #660 ~432 | #737 ~445 | #826 ~470 | #902 ~495 | #978 ~508 | #1067 ~533 | #1143 ~546 | #1218 ~559 | #1308 ~572 | #1379 ~604 | #1461 ~610 | #1531 ~621 | #1626 ~635 | |||||||||
305 | #635 ~457 | #711 ~483 | #787 ~508 | #876 ~533 | #953 ~559 | #1029 ~572 | #1118 ~597 | #1189 ~625 | #1270 ~635 | #1349 ~662 | #1435 ~673 | #1511 ~696 | #1600 ~699 | #1660 ~716 | #1753 ~724 | #1820 ~742 | #1918 ~762 | #1981 ~784 | |||||
356 | #686 ~508 | #762 ~546 | #838 ~572 | #927 ~597 | #1003 ~622 | #1080 ~648 | #1165 ~671 | #1245 ~680 | #1320 ~713 | #1410 ~724 | #1481 ~752 | #1562 ~762 | #1646 ~787 | #1727 ~787 | #1802 ~821 | #1892 ~846 | #1952 ~850 | ||||||
406 | #648 ~533 | #737 ~572 | #813 ~597 | #889 ~622 | #978 ~660 | #1054 ~686 | #1131 ~710 | #1219 ~724 | #1291 ~757 | #1375 ~775 | #1452 ~800 | #1537 ~813 | #1612 ~840 | #1702 ~851 | #1773 ~877 | #1854 ~921 | #1923 ~943 | ||||||
457 | #711 ~584 | #787 ~622 | #864 ~660 | #940 ~686 | #1029 ~711 | #1102 ~745 | #1181 ~762 | #1267 ~797 | #1346 ~813 | #1423 ~844 | #1511 ~851 | #1583 ~887 | #1664 ~902 | #1750 ~928 | #1829 ~947 | #1894 ~970 | |||||||
508 | #749 ~635 | #838 ~673 | #914 ~711 | #1003 ~737 | #1073 ~775 | #1156 ~800 | #1241 ~830 | #1321 ~851 | #1394 ~882 | #1473 ~902 | #1554 ~934 | #1638 ~940 | #1724 ~974 | #1803 ~978 | #1865 ~1003 | ||||||||
610 | #1087 ~876 | #1168 ~900 | #1248 ~910 | #1327 ~940 | #1708 ~965 | #1486 ~995 | #1567 ~1006 | #1646 ~1032 | #1726 ~1040 | #1807 ~1062 |
OVAL DUCT – SPECIFICATIONS
FLAT OVAL DUCT CONSTRUCTION FOR POSITIVE-PRESSURE DUCT SYSTEM
MINIMUM GALVANIZED STEEL THICKNESS
Thickness: 0.50(26G) to 1.2 mm (18G). Thickness of flat-oval spiral ducts as per SMACNA “HVAC DUCT CONSTRUCTION STANDARDS” -2005
Standard Length : 4,8,10 and 12ft. length
Material : Galvanized steel, mild steel (CR), Aluminium, stainless steel etc.
Surface constructions : Plain or corrugated (to increase the radial rigidity of the duct by 300%.
Surface finish : Powder Coated, Painted.
I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Major Axis (mm) | Spiral Seam Duct | Longitudinal Scam Duct | Fitting | Suggested type of joint |
---|---|---|---|---|
610 | 24 SWG | 22 SWG | 20 SWG | Groove Slip Connector |
915 | 22 SWG | 22 SWG | 20 SWG | Groove Slip Connector |
1220 | 22 SWG | 20 SWG | 20 SWG | Flange |
1525 | 20 SWG | 20 SWG | 20 SWG | Flange |
1780 | 20 SWG | 18 SWG | 18 SWG | Flange |
1780 Over | 18 SWG | 16 SWG | 18 SWG | Flange |